CCVKG - NIPOL NITRILE (NBR) ELASTOMERS, 1041U
- MSDS: CCVKG
- Manufacturer: ZEON CHEMICALS INC
- Product Name: NIPOL NITRILE (NBR) ELASTOMERS, 1041U
- National Stock Number: 9320-00N075602
Product Identification
Product ID:NIPOL NITRILE (NBR) ELASTOMERS, 1041U
MSDS Date:01/13/1994
FSC:9320
NIIN:00N075602
MSDS Number: CCVKG
Responsible Party
ROLLING MEADOWS, IL 60008
US
Emergency Phone: 800-776-2460
Info Phone: 800-735-3388
Cage: 0J3F9
Contractor
Telephone: 800-735-3388/502-775-2000
Cage: 0J3F9
Ingredients
< 20 PPM
CAS: 107-13-1
RTECS: AT5250000
Fraction By Weight: <0.1%
OSHA PEL SEE 1910.1045
ACGIH TLV: 2 PPM, A2, S
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
< 5 PPM
CAS: 106-99-0
RTECS: EI9275000
Fraction By Weight: <0.1%
OSHA PEL 1000 PPM
ACGIH TLV: 2 PPM; A2
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ACRYLONITRILE BUTADIENE POLYMER
CAS: 9003-18-3
Fraction By Weight: <100%
OSHA PEL N/K
ACGIH TLV: N/K
FORMED INTO FINE POWDER. HYDROGEN CYANIDE GAS IS
RTECS: 9999999ZZ
ORGANIC COMPOUNDS, ARE NOT COMPATIBLE WITH
RTECS: 9999999ZZ
AROMATIC & ALIPHATIC HYDROCARBONS.
RTECS: 9999999ZZ
NATURAL AND SYNTHETIC MATERIALS, MUST BE CONSIDERED
RTECS: 9999999ZZ
SUCH AS COUGHING, TEARING & IRRIT SHOULD BE
RTECS: 9999999ZZ
INDIVIDUAL TO FRESH AIR. CONSULT MD
RTECS: 9999999ZZ
FOOD IN PROCESSING AREAS. DO NOT USE PROCESSING
RTECS: 9999999ZZ
PROCESSING SHOULD BE PERFORMED UNDER WELL-VENTD
RTECS: 9999999ZZ
SHORT TIME W/OUT SIGNIFICANT THERMAL DEGRADATION.
RTECS: 9999999ZZ
ELEVATED TEMPS/EXCESS TIME WILL RSLT IN DECOMP.
RTECS: 9999999ZZ
W/CMPD IN IT/DECOMP WILL OCCUR. PROCESSING FUME
RTECS: 9999999ZZ
COMBUST & SHOULD BE PERIODICALLY REMOVED FROM EXHST
RTECS: 9999999ZZ
PURCHASED TO ADD TO ELASTOMER PRODS MAY REQUIRE
RTECS: 9999999ZZ
PREC OF INDIVIDUAL ADDITIVE SUPPLIERS.
RTECS: 9999999ZZ
WORKPLACE INVOLVING HEAT SUFFICIENT TO RSLT IN
RTECS: 9999999ZZ
BE CONDUCTED IN SUCH A MANNER TO AVOID INHAL OF
RTECS: 9999999ZZ
SIGNIFICANT EMPLOYEE EXPOS. STORE IN COOL, DRY
RTECS: 9999999ZZ
DURING PROCESSING MAY CAUSE DECOMP. IF GEN
RTECS: 9999999ZZ
PROVIDE EMPLOYEES W/SUITABLE AIR SUPP RESPS, SUCH
RTECS: 9999999ZZ
ROUTINE INHAL. VENT MUST BE ADEQ TO MAINTAIN AMBIENT
RTECS: 9999999ZZ
MAY BE FOUND IN PUBLICATIONS SUCH AS INDUS VENT,
RTECS: 9999999ZZ
HYGIENISTS, 6500 GLENWAY AVENUE, BLDG. D-7,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: OVEREXP NOT EXPECTED AT AMBIENT
TEMPS. NO ADVERSE HLTH EFTS ARE EXPECTED DURING NORM PROCESSING
WHEN POTENTIAL EXPOS ARE ELIM BY GOOD INDUS HYGIENE PRACT &
WELL-VENTD CNDTNS. AT PROCESSING TEMP S, COMBINED INGS (ELASTOMER &
OTHER PROCESSING INGS) MAY EMIT FUMES & VAPS THAT CAUSE IRRIT TO
RESP (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TRACT, EYES &/SKIN. TYPICALLY THESE
EFTS ARE REVERSIBLE UPON REMOVAL FROM EXPOS & NO LASTING EFTS ARE
EXPECTED. MOST IMPORTANT, POTENTIAL FOR IRRIT WILL DEPEND ON
EFFECTIVENESS OF EXHST VENT PROVIDED TO PROCESS AREA. OVEREXP TO
DECOMP/COMBUST PRODS WILL CAUSE IRRIT OF RESP TRACT, EYES & SKIN.
SYMPS (ING 8)
Medical Cond Aggravated by Exposure:NONE KNOWN FOR PRODUCTS AS
DELIVERED.
First Aid
First Aid:IF IRRIT OCCURS/PERSISTS FROM ANY RTE OF EXPOS, REMOVE
AFFECTED INDIVIDUAL FROM AREA. CALL MD. PROVIDE PROT BEFORE
ALLOWING REENTRY. EYE: FLUSH W/RUNNING WATER FOR AT LEAST 15 MIN
WHILE HOLDING EYELID S OPEN. CONSULT MD IF IRRIT PERSISTS. SKIN:
REMOVE CONTAM CLTHG. WASH SKIN W/SOAP & WATER. NO EFTS REQUIRING
FIRST AID ARE EXPECTED. INHAL (PROCESSING VAPS/DECOMP PRODS):
REMOVE AFFECTED (ING 9)
Fire Fighting
Extinguishing Media:WATER, ABC DRY CHEM/PROTEIN TYPE AIR FOAMS ARE REC
MEDIA. ELASTOMERS WOULD BE CONSIDERED "ORDINARY COMBUSTS" (SUP DAT)
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
PERS NOT HAVING SUITABLE RESP PROT MUST LEAVE AREA TO PVNT
SIGNIFICANT EXPOS TO TOX COMBUST GASES (SUP DAT)
Unusual Fire/Explosion Hazard:MOST ORG SUBSTANCES WHEN IN THE FORM OF A
LINE DUST/POWDER PRESENT DUST EXPLO HAZ. SPECIAL PREC MUST BE TAKEN
IF THESE ELASTOMERS ARE GROUND/OTHERWISE (ING 4)
Accidental Release
Spill Release Procedures:SWEEP, SHOVEL, OR VACUUM CRUMBS OR CHUNKS INTO
CLOSED CONTAINERS FOR REUSE OR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DURING NORM PROCESSING, VIRTUALLY ALL
ELASTOMERS WILL EMIT FUMES & VAPS WHEN HEATED TO PROCESSING TEMPS.
Other Precautions:CONC & COMPOSITION OF THESE VAPS WILL DEPEND ON
VARIABLES SUCH AS SPECIFIC FORMULATION & PROCESSING METH & TEMP.
ALWAYS PROCESS ELASTOMERS UNDER WELL-VENTD CNDTNS & AVOID
CONTINUED/PRLNG BRTHG OF PROC ESS VAPS. DO NOT STORE/CONSUME (ING
10)
Exposure Controls
Respiratory Protection:AS SUPPLIED, RESP PROT IS NOT TYPICALLY REQUIRED
DURING NORM USE & HNDLG OPERATIONS. RESP PROT MAY BE NEEDED IF PROD
IS GROUND INTO FIRE POWDER/DUST. ABNORM CNDTNS SUCH AS EQUIP
MALFUNCTION, IMPROPER EQUIP/PROC/HANGUP/STAGNATION (ING 21)
Ventilation:EFFECTIVE GEN &, IF NEC, LOC EXHST VENT MUST ALWAYS BE
PROVIDED TO DRAW FUMES/VAPS AWAY FROM WORKERS TO PVNT (ING 23)
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
PROT CLTHG SHOULD BE WORN DURING CLEANUP OPERATIONS TO PVNT SKIN
CONT.
Work Hygienic Practices:WASH THOROUGHLY AFTER PROCESSING COMPOUND,
ESPECIALLY BEFORE EATING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
EXTING MEDIA:(NFPA DEFINED CLASS A). CARBON DIOXIDE IS GEN NOT REC FOR
USE ON CLASS A FIRES AS A LACK OF COOLING CAPACITY MAY RSLT IN
REIGNIT. FIRE FIGHT PROC:FROM ANY SOURCE. IN ENCLSD/POORLY VENTD A
REAS, WEAR NIOSH APPRVD SCBA DURING CLEANUP IMMED AFTER FIRE AS
WELL AS DURING ATTACK PHASE OF FIREFIGHTING OPERATIONS.
Chemical Properties
Spec Gravity:1.0 (H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:TAN TO BROWN SLAB WITH A MILD CHARACTERISTIC ODOR
Stability
Stability Indicator/Materials to Avoid:YES
NO SPECIFIC INFO IS AVAIL, HOWEVER STRONG OXIDIZERS/REDUCING AGENTS
WHICH ARE GENERALLY NOT COMPATIBLE W/MANY (ING 5)
Stability Condition to Avoid:OVERHEATING.
Hazardous Decomposition Products:FUMES PRODUCED WHEN HEATED TO DECOMP
TEMPS MAY CONTAIN: OXIDES OF CARBON, HYDROGEN CYANIDE, & SML AMTS
OF (ING 6)
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.